PLATFORM WILL NOT UNFOLD - Continued
TROUBLESHOOTING
6. Check for damage and corrosion at platform
pivot points. Steam clean corrosion from
pivot points. Replace bushings at pivot points
if required.
7. Check for bent and broken parts on the
Liftgate that could interfere with normal
operation. Look at columns, runners, tandem
rollers and platform (bent pins).
5. Verify that relief valve pressure settings are
correct. Refer to RELIEF VALVE PRESSURE
SETTING procedure in this manual. Also,
make sure opening fl ow control valve (in
pump) is open. If correct pressure settings
cannot be made or if pump runs hot with
excessive noise, replace pump.
TYPICAL SOLENOID VALVE
REMOVED & DISASSEMBLED
FIG. 70-1
COIL
VALVE
CARTRIDGE
CHECKING VALVE CARTRIDGE
FIG. 70-2
VALVE
CARTRIDGE
1/8”
8. Check for bent or weak platform torsion
spring. Replace if necessary.
NUT