PLATFORM RAISES AND LOWERS UNEVENLY
TROUBLESHOOTING
1. Reverse the two 3/8” high pressure hose
connections on output side of fl ow divider as
shown in FIG. 62-1. Raise the platform. If
the uneven platform position is the opposite
of original symptom, replace fl ow divider.
FLOW
DIVIDER
LIFTING
CYLINDER
HOSES
HOSE CONNECTIONS ON
FLOW DIVIDER
FIG. 62-1
2. Check each Lifting hydraulic cylinder.
NOTE: Do the BLEEDING HYDRAULIC
SYSTEM procedure in this manual
with the following step.
POWER DOWN LIFTGATES: Raise the platform to bed height. Disconnect both
bottom POWER DOWN RETURN HOSES at the “T” connector between pump
box and bottom of each cylinder. (Refer to POWER DOWN HYDRAULIC LINES
IDENTIFICATION in this manual. Place a large container to catch fl uid from both
hoses. Set control box toggle switch to UP position to raise platform. Check if fl uid
is streaming from the hoses. A few drops of hydraulic fl uid is okay; however, if fl uid
streams steadily from a hose, replace piston seals in the cylinder connected to that
hose.
GRAVITY DOWN LIFTGATES: Lower the platform to the ground. Disconnect the
RETURN HOSE at the bottom of each column. Place a large container under
cylinder to catch fl uid. Set control box toggle switch to UP position to raise platform.
Check if fl uid is streaming from the fi tting. A few drops of hydraulic fl uid is okay;
however, if fl uid streams steadily from the fi tting, replace piston seals.